Pressure Transducer Sender Stainless Steel 0-4.5V For Oil Fuel Air Water
Pressure Transducer Sender Stainless Steel 0-4.5V For Oil Fuel Air Water
5psi/15psi/30psi/60psi/100psi/150psi/200psi/300psi/500psi/1000psi/1600psi
11 type for your choice
Features
100% brand new and high quality
Works for oil,fuel,diesel,gas,water,air pressure.
Can be used in oil tank,gas tank,diesel tank etc.
It's an advance pressure sender than traditional mechanical pressure sender;
CMC for Load Cell Sensor;
CMC for Pressure and Pull Pressure Sensor.
Specifications:
Material: Stainless steel body.
5 psi
Input: 0-5 psi(Gauge Pressure);
Output: 0- 4.5V linear voltage output. 0 psi outputs 0.5V, 2.5 psi outputs 2.5V, 5 psi outputs 4.5V.
Accuracy: +/-0.5%FS;
Thread: 1/8” NPT;
Wiring Connector: Packard plug-in unit is included;
Wiring: Red: +5V; Black: ground; Green: signal output;
Overload Capacity: 2-4 times;
Working Temperature: -40—+120ºC;
Compensation Temperature: -20—+80ºC;
Protection Class: IP67;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤(supply power-6.5V/0.02A)Ω;
Long-term stability: Less than 0.1%FS/year;
Temperature Effect on Zero: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Shock Resistance: 1000g;
Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mΩ 500VDC;
Weight: 55 g
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50051-1.
15 psi
Input: 0-15 psi(Gauge Pressure);
Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 7.5 psi outputs 2.5V, 15 psi outputs 4.5V.
Accuracy: +/-0.5%FS;
Thread: 1/8” NPT;
Wiring Connector: Packard plug-in unit is included;
Wiring: Red: +5V; Black: ground; Green: signal output;
Overload Capacity: 2-4 times;
Working Temperature: -40—+120ºC;
Compensation Temperature: -20—+80ºC;
Protection Class: IP67;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤ (supply power-6.5V/0.02A)Ω;
Long-term stability: Less than 0.1%FS/year;
Temperature Effect on Zero: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Shock Resistance: 1000g;
Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mΩ 500VDC;
Weight: 55 g
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50051-1.
30 psi
Input: 0-30 psi.
Output: 0.5V – 4.5V linear voltage output. 0 psi outputs 0.5V, 15psi outputs 2.5V, 30 psi outputs 4.5V.
Accuracy: within 2% of reading (full scale).
Thread: 1/8”-27 NPT.
Wiring connector: water sealed quick disconnect. Mating connector is included.
Wiring: Red for +5V. Black for ground. Blue for signal output.
Weight: 55 g
60 psi
Input: 0-60 psi(Gauge Pressure);
Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 30 psi outputs 2.5V, 60 psi outputs 4.5V.
Accuracy: +/-0.5%FS;
Thread: 1/8” NPT;
Wiring Connector: Packard plug-in unit is included;
Wiring: Red: +5V; Black: ground; Green: signal output;
Overload Capacity: 2-4 times;
Working Temperature: -40—+120ºC;
Compensation Temperature: -20—+80ºC;
Protection Class: IP67;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤(supply power-6.5V/0.02A)Ω;
Long-term stability: Less than 0.1%FS/year;
Temperature Effect on Zero: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Shock Resistance: 1000g;
Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mΩ 500VDC;
Weight: 55 g
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50051-1.
100 psi
Input: 0-100 psi.
Output: 0.5V – 4.5V linear voltage output. 0 psi outputs 0.5V, 50 psi outputs 2.5V, 100 psi outputs 4.5V.
Accuracy: within 2% of reading (full scale).
Thread: 1/8”-27 NPT.
Wiring connector: water sealed quick disconnect. Mating connector and wire harness (pigtail) is included.
Wiring: Red for +5V. Black for ground. Blue for signal output.
Weight: 55 g
150 psi
Input: 0-150 psi(Gauge Pressure);
Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 75 psi outputs 2.5V, 150 psi outputs 4.5V.
Accuracy: +/-0.5%FS;
Thread: 1/8” NPT;
Wiring Connector: Packard plug-in unit is included;
Wiring: Red: +5V; Black: ground; Green: signal output;
It's an advance pressure sender than traditional mechanical pressure sender;
Overload Capacity: 2-4 times;
Working Temperature: -40—+120ºC;
Compensation Temperature: -20—+80ºC;
Protection Class: IP67;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤ (supply power-6.5V/0.02A)Ω;
Long-term stability: Less than 0.1%FS/year;
Temperature Effect on Zero: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Shock Resistance: 1000g;
Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mΩ 500VDC;
Weight: 55 g
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50051-1;
200 psi
Pressure Range: 0-200 psi
Output: 0.5V – 4.5V linear voltage output. 0 psi outputs 0.5V, 100 psi outputs 2.5V, 200 psi outputs 4.5V
Working Temperature: -40—+125ºC;.
Accuracy: ±1%FS;
Thread: 1/8”-27 NPT.
Overload Capacity: 2 times;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤(supply power-6.5V/0.02A)Ω;
Long-term stability: ± 0.2%FS/year;
Temperature Effect on Zero: Typical: ±0.02%FS/ºC; Maximum: ±0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical: ±0.02%FS/ºC; Maximum: ±0.05%FS/ºC;
Shock Resistance: 100g;
Anti-Shock: ≤±0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mΩ 500VDC;
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50081-1; EN50082-2; IEC6 1000-4-3 ;
Wiring connector: water sealed quick disconnect. Mating connector and wire harness (pigtail) is included.
Wiring: Red for IN+. Black for GND. Green for OUT.
Weight: 55 g
300psi
Input: 0-300 psi(Gauge Pressure);
Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 150 psi outputs 2.5V, 300 psi outputs 4.5V.
Accuracy: +/-0.5%FS;
Thread: 1/8” NPT;
Wiring Connector: Packard plug-in unit is included;
Wiring: Red: +5V; Black: ground; Green: signal output;
Overload Capacity: 2-4 times;
Working Temperature: -40—+120ºC;
Compensation Temperature: -20—+80ºC;
Protection Class: IP67;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤ (supply power-6.5V/0.02A)Ω;
Long-term stability: Less than 0.1%FS/year;
Temperature Effect on Zero: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Shock Resistance: 1000g;
Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mΩ 500VDC;
Weight: 55 g
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50051-1.
500 psi
Input: 0-500 psi(Gauge Pressure);
Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 250 psi outputs 2.5V, 500 psi outputs 4.5V.
Accuracy: +/-1%FS;
Thread: 1/8” NPT;
Wiring Connector: Packard plug-in unit is included;
Wiring: Red: +5V; Black: ground; Yellow(Green): signal output;
Overload Capacity: 2-4 times;
Working Temperature: -40—+120ºC;
Compensation Temperature: -20—+80ºC;
Protection Class: IP67;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤ (supply power-6.5V/0.02A)ω;
Long-term stability: Less than 0.1%FS/year;
Temperature Effect on Zero: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Shock Resistance: 1000g;
Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mω 500VDC;
Weight: 71 g
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50051-1.
1000 psi
Input: 0-1000 psi.
Output: 0.5V – 4.5V linear voltage output. 0 psi outputs 0.5V, 500 psi outputs 2.5V, 1000 psi outputs 4.5V.
Works for oil, fuel, water or air pressure. Can be used in oil tank, gas tank, etc.
Accuracy: within 2% of reading (full scale).
Thread: 1/8”-27 NPT.
Wiring connector: water sealed quick disconnect. Mating connector is included.
Wiring: Red for +5V. Black for ground. Blue for signal output.
Weight: 71 g
1600psi
Input: 0-1600 psi(Gauge Pressure);
Output: 0.5-4.5V linear voltage output. 0 psi outputs 0.5V, 800 psi outputs 2.5V, 1600 psi outputs 4.5V.
Accuracy: +/-0.5%FS;
Thread: 1/8” NPT;
Wiring Connector: Packard plug-in unit is included;
Wiring: Red: +5V; Black: ground; Green: signal output;
Overload Capacity: 2-4 times;
Working Temperature: -40—+120ºC;
Compensation Temperature: -20—+80ºC;
Protection Class: IP67;
Pressure Medium: The gas and liquid which is compatible with 316L stainless steel;
Load Resistance: ≤ (supply power-6.5V/0.02A)Ω;
Long-term stability: Less than 0.1%FS/year;
Temperature Effect on Zero: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Temperature Effect on Sensitivity: Typical:0.02%FS/ºC; Maximum:0.05%FS/ºC;
Shock Resistance: 1000g;
Anti-Shock: ≤+/-0.01%FS(X,Y,Z axes, 200Hz/g);
Response Time: ≤1ms;
Insulation Resistance: >100mΩ 500VDC;
Weight: 100 g
Explosion-proof Class: ExiaTTCT6;
Electromagnetism Compatibility: EN50051-1.
Package included
1X Pressure transducer (With cable)