See Details on eBay

Fluke 1587 Mdt Fc Advanced Motor & Drive Troubleshooting Kit I400 Clamp 9040

$1,318.52 or Best Offer 3d 12h, $96.08 Shipping, 30-Day Returns

Seller: computer_psycho (13,647) 100%, Location: Van Nuys, California, Ships to: Worldwide, Item: 232747039810 SERIOUS BUYERS ONLY! PLEASE READ STORE DETAILS CAREFULLY! *** BRAND NEW *** FLUKE 1587 MDT FC ADVANCED MOTOR AND DRIVE TROUBLESHOOTING KIT WITH FLUKE CONNECT I400 CURRENT CLAMP & FLUKE 9040 PHASE ROTATION INDICATOR Item Details: Manufacturer: FLUKE Description from Manufacturer: The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app: Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets The Fluke i400 AC Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings. Fluke 9040 Phase Rotation Indicator is effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications. Includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit Check the rotation of three-phase motors easily and safely with the Fluke 9040 The Fluke 1587 FC 2-in-1 Insulation DMM Pl/DAR measurements with TrendIt™ graphs Memory storage through Fluke Connect Measurements app Temperature Compensation through Fluke Connect Measurements app VFD low-pass filter for accurate motor drive measurements Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V Insulation test voltages 500 V, 1000 V Insulation test: 0.01 MΩ to 2.0 GΩ Insulation test: 0.1 MΩ to 600 MΩ Auto-discharge of capacitive voltage Insulation test smoothing reading Frequency / Capacitance / Diode test / Temperature Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps Resistance (0.1 Ω to 50 MΩ) / Continuity / Auto power off Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case Fluke i400 AC Current Clamp Use with your Fluke 1587 FC to measure 1A AC to 400 A AC 1 mA/Amp output guarantees easy reading CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection Specially designed to offer maximum utility in a very compact shape Maximum conductor: Ø 32 mm 1 year warranty Fluke 9040 Phase Rotation Indicator Large display to easily determine field rotation and phase sequence Indication for all three phases CAT III 600 V overvoltage rating 2 year warranty Fluke 1587 FC Insulation Multimeter Electrical Specifications AC voltage measurement Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ ¹ 1 kHz bandwidth Low-Pass Filter Voltage Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) DC Voltage Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 6.000 V dc 0.001 V ±(0.09% + 2) 60.00 V dc 0.01 V ±(0.09% + 2) 600.0 V dc 0.1 V ±(0.09% + 2) 1000 V dc 1 V ±(0.09% + 2) Input impedance 10 MΩ (nominal), 60 dB @ 50 Hz or 60 Hz Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) Accuracies apply to ± 100% of range DC Millivolts Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 600.0 mVdc 0.1 mV ±(0.1% + 1) DC and AC Current Measurement AC 45 Hz to 1000 Hz Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA DC Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Overload 600 mA for 2 minutes maximum Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. ¹ 1 kHz bandwidth Ohms Measurement Range Resolution Accuracy +(% of Rdg+Counts)¹ 600.0 Ω 0.1 Ω ±(0.9% + 2) 6.000 kΩ 0.001 kΩ ±(0.9% + 2) 60.00 kΩ 0.01 kΩ ±(0.9% + 2) 600.0 kΩ 0.1 KΩ ±(0.9% + 2) 6.000 MΩ 0.001 MΩ ±(0.9% + 2) 50.0 MΩ ² 0.01 MΩ ±(1.5% + 3) Overload protection 1000 V rms or dc Open circuit test voltage Condition: New, Brand: Fluke, Model: 1587 MDT FC, MPN: 4692716, UPC: 09596979728

PicClick Insights PicClick Exclusive
  •  Popularity - 2,142 views, 18.3 views per day, 117 days on eBay. Super high amount of views. High amount sold, 5 Sold, 1 Available.
  •  Price -
  •  Seller - 13,647+ items sold. 0% negative feedback. Top-Rated Seller! Ships on time with tracking, 0 problems with past sales.
Similar Items