Easyinsmile Dental Endo Activator Sonic Irrigator Never Break 60 tips Bendable

$169.00 Buy It Now, FREE Shipping, 30-Day Returns, eBay Money Back Guarantee
Seller: easyinsmiledental ✉️ (323) 98.8%, Location: VIC, AU, Ships to: WORLDWIDE, Item: 404420705467 Easyinsmile Dental Endo Activator Sonic Irrigator Never Break 60 tips Bendable . Package List: Main Unit 1 PC Protective Barrier 100 PCS Needle Tips: 2/15 20 PC 4/25 20 PC 4/35 20 PC 1. Indications For user The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm. The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success.
ultrasonic activatior       Package List: First generation Main Unit 1 PC Protective Barrier 100 PCS Needle Tips: 2/15  20 PC 4/25  20 PC 4/35  20 PC   Second generation: Main Unit 1 PC Protective Barrier 100 PCS Needle Tips: 2/15  15 PC 4/25  15 PC 4/35  15 PC   1. Indications For user The Easydo Activator system uses technology of sonic energy for root canal  treatment. The driver work with the Hand device, motor and needle tip to  provide power for tip oscillation and vibration. Evidence-based endodontics  has shown that cavitation and acoustic streaming can improve debridement  and the disruption of the smear layer and biofilm. The Activator helps the  fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal,  Connection of inter-root canal and root apex to ensure deep cleaning and  sterilization of root canal. It is beneficial to complete the 3D filling of the  root canal and ensures long-term success. 2. Notice 1) Remove the needle tip of EasyDO Activator. If your treatment process is over, please leave it for medical recycling. 2) Please put exhaustively discharged battery into the recycling box. 3 ) Do not submerge the unit in water. 4 ) Do not autoclave the unit. 3. Precautions 1) The EasyDO Activator system is only used by dental professionals. 2) The EasyDO Activator system is comprised of the Hand device and  Activator needle tips of various sizes. If the system functions are used  correctly, the equipment can maintain a normal operation. It is strictly  prohibited to use non-original components, which will damage the  equipment and make it unable to work normally. The original components  include the Easydo activator hand device, needle tip and protective cover. The Easy smile reference number of the  hand device  EASYDO Activator-M10821 The reference numbers of the EasyDO Activator Needle tip M10822-015 (Small) M10822-025 (Medium) M10822-035 (Large)   3 ) The handle device provides three speeds sonic motor adjustment options (High, Med, Low). The speed gears switch setting adjustment is ultimately determined by the procedure to be performed, the cliniclan' experience can efficiently complete the clinical task. 4) The handle device don’t require calibration for normal use. 5) All clinical treatment should be performed with Easydo activator protective barrier sleeve that placed over the hand device. 6) In the course of treatment, we should use sterilized and individually packed needle tip, otherwise it will cause root canal infection. 7) It is necessary to use EasyDO Activator system correctly a ccording to treatment specifications and operation manual to prevent injury to patients. 8) Improper using of the hand device may result in broken handle of the equipment and damage of internal components. 9) The EasyDO Activator needle tips and protective sleeve are intended for single-patient use only. Cross contamination may occur to the patient if needle tips and protective barriers are re-used.     4. Warranty information of EasyDO activator 1 ) The EASY IN SMILE company provides users with quality assurance  within one year from the date of purchase of this product. In case of any failure due to the defect of Hand device material or production process of the mainframe within this year, the EASY IN SMILE company will  provide equipment repair or replacement products. 2 ) The warranty does not include consumables such as needles,  batteries, etc. 3 ) If the equipment is damaged due to improper use and maintenance, or maintenance personnel repair or change of spare parts without the authorization of EASY IN SMILE, the warranty policy is invalid. 4 ) Under any condition, neither EASY IN SMILE nor its affiliates are responsible for any special, incidental, or consequential liability resulting from a violation of the warranty policy, contract, or any other legal policy. Such damages include but are not limited to loss of investment, loss of profits, loss caused by wrong use of product functions, etc.; including but not limited to third party claims and increase of service cost caused by any alternative equipment, etc.   5 ) Warranty limitations Content not covered by warranty: -Needle tip -Hand device barrier sleeve -Damage caused by misuse, abuse, neglect of prompt or change of the equipment usage -Normal wear and other external scratches, including scratches, wear, cracks, discoloration or fade. -Battery replacement * Note: If the product is not used for a long time (two weeks or longer), please remove the battery. It also must be removed during transport, for example, during delivery   10) Properly dispose the Activator needles tip and hand device protective barriers in accordance with the local laws and regulations and environmental protection requirements. 11) Dispose the battery after being used in accordance with the local laws and regulations and environmental protection requirements, when battery is exhausted. 12) The hand device must be repaired if necessary according to the direction of the manufacturer. 13) Don’t insert needle tip into the hand device. If the equipment is not used for a long time, placing the hand device into packing box is recommended. 14) Remove the battery when the hand device is not used for a long time. 15) The hand device can be kept at the temperature of 0 ℃ ~ 55 ℃ , relative humidity 0% ~ 75% RH and air pressure750-1060 HPA. 16) The hand device should be keep away from strong electromagnetic interference, which may affect the performance and normal use of hand device. 17) The hand device should be kept away from portable or mobile RF communication devices, which may affect the performance of hand device . 18) The hand device could not be adjacent to or stored with other equipment. In addition, it is necessary to check regularly whether the hand device can work normally. 19) Proper disposal of the hand device is required when the hand piece is deemed no-functional in accordance with local laws and regulations. 6.Product parameters Name EasyDO Activator Model EASYDO Activator-M1082 Function Debridement / disinfection / root canal therapy Use environment Indoor environment; Temperature range: 0 ℃ ~ + 55 ℃ ; Relative Humidity: 0% ~ 75% RH; Air Pressure: 750-1060 HPA Power Supply DC : 1.0v~1.5v Battery AA grade LR6, 1.5v mercury-free alkaline dry battery Size L 183mm * W 23mm * H43.1mm Gross Weight 124g 7.Operation / Step Preparation: 1) Prepare the root canal to produce a fully tapered shape. 2) Fill pup chamber with NaOCI, EDTA, or final rinse soulution. 3) Select the needle tip that manually fits loosely within 2mm of the working length. 4) Place the barrier sleeve over the complete length of the hand device. 5) Connect the needle tip to the hand device with the barrier sleeve. The activator should snap on firmly, promoting a secure connection with the hand device. 6) Press ON/OFF button for 1 second, you can see the battery power status. If the power is enough, you can continue the treatment. If the power is not enough, you need to replace the battery. 7) Place the attached needle tip into the prepared root canal. 8) Drepress the ON/OFF button to actvate. Switch defaults to high speed upon activation. Depress the 3-speed switch to select medium speed or low speed. 9) Use a pumping action to move the hand device in short 2~3 mm vertical strokes. 10) Hydro dynamically agitate the medical solution for about 30-60 seconds. 11) After washing, use a suction pipe to remove loose debris and sundries from the root canal. 12) Repeat the above steps for each different root canal treatment. * when the clinical procedure has been completed, remove the protective barrier sleeve, remove the needle tip and store it in the medical waste recycling box. The needle tip and protective sleeve are intended for single-patient used only. Other instructions: if the EasyDO Activer hand device has been working for 8 minutes without any operation, or there is no operation after the equipment stops working, it will enter the state of self-protection system and power oFF. If you need it to restart , please depress the ON/OFF switch. 8. Key points of Operation: 5.1 ) POWER OF BATTERY STATUS Depress the " ON / OFF Switch" key for 1 second to observe the "Power Indicator" status around the button of the hand device. 1. If the "Power Indicator" is white, it means the activator system is in full power status; 2. if the "Power Indicator" is red and white, it means the system is in half power status; 3. if the "Power Indicator" is red, it means the system is in power shortage status; 4. If the "Power Indicator" is flashing red, it indicates that the system is on the verge of power failure. 5. Please note if the "power indicator" is flashing red, please replace the battery.   PaymentDelivery detailsTerms of salesAbout usContact usPayment With Paypal,you can pay easily,quickly and securly.
Please pay as soon as possible if you like the products,as that will allow us to post your item to you sooner.

Tips: Shipping Combine is Provided

How to make a Shipping Combine?
  Step1: Add the items to your cart.
  Step2: Click the "Request total from seller"
  Step3: Wait for the invoice form seller.
  Step4: Make a payment after receive the invoice. Delivery details

1. The package will be posted within 1 working days .

2. About 5-8 days delivery from AU warehouse, if the item location is in Australia.(Please contact us if you didn’t receive it within 15 days.)

3. About 20-28 days delivery from CN warehouse, if the item location is in China. (Please contact us if you didn’t receive it with in 35 days.)

4. Tracking number is provided, you can check it online.

5. Please make sure that the delivery address is correct.

6. Please be advised that some items aren’t ship able to P.O.Box because the size of the item.

7. Any problems, welcome to contact us. We'll help you. Terms of sales About Warranty:   We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.   Return Policy   If you receive a defective item which you want to return, please contact us within 2 days from the day you receive the item. All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return. We will refund the money to you when we get the return items. Or replace item for you free of charge.   Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.   About us Easyinsmile(USA)International Corp. is a professional Large-scale Manufacturer of all types of dental instruments and related products,i ntegrating development and production.Our company regards"Reasonable prices,efficient production time and good after sale service" as our tenet.We hope to cooperate with more customers for mutual development and benefits.We welcome potential buyers to contact us. Contact us We always go for 100% customer satisfaction.Postive feedback means a lot to us. If you have any queries,please contact us via Ebay.We will reply you as soon as possible. We will appreciate it if you please email us before leaving any negative feedback.If there is any problem,we can work together to resolve it.
  • Condition: Brand New
  • Model: Full kit 1st generation
  • Brand: Easyinsmile
  • Intended Use/Discipline: Dental Laboratory, Dentistry, Endodontics, Orthodontics
  • Type: Endo ultrasonic activator
  • Country/Region of Manufacture: China
  • 60 Tips free: Yes
  • warranty: 1 year for Main Unit
  • Evenly apply medicine: Yes
  • Instrument: Endodontic Explorer

PicClick Insights - Easyinsmile Dental Endo Activator Sonic Irrigator Never Break 60 tips Bendable PicClick Exclusive

  •  Popularity - 0 watchers, 0.0 new watchers per day, 238 days for sale on eBay. 0 sold, 10 available.
  •  Best Price -
  •  Seller - 323+ items sold. 1.2% negative feedback. Great seller with very good positive feedback and over 50 ratings.

People Also Loved PicClick Exclusive